Hangzhi High Accuracy AC & DC Voltage Transducer
De HCV high precision AC & DC voltage transducer developed by HANGZHI is a voltage measurement and control component based on fluxgate-technologie. It is also a type of isolated voltage transducer that can accurately measure DC, AC, pulse and various irregular voltages under the condition of complete isolation between the primary and secondary sides, which is a voltage sensor with extremely high measurement accuracy in the industrial field. It is mainly used in the fields of metrological verification and calibration, as well as rail transportation, power quality analysis, power analyzers, medical equipment, aerospace, naval vessels and other fields that require high sensitivity, high stability and high reliability.
Key Technical Parameter of HCV high voltage sensor:
- 0.2% accuracy;
- 0.05% linearity;
- Range up to 10000V;
What is Voltage Transducer?
A voltage transducer is a device or sensor that is used to convert a voltage signal to another form of signal that measureable by instruments and controllers. It is commonly employed in electrical and electronic systems to measure, monitor, or control voltage levels. Voltage transducers can serve various purposes, including voltage measurement, voltage scaling, voltage isolation, and voltage conversion.
Key Features of HCV High precision voltage sensor
De high-precision high-voltage sensor developed by HANGZHI is a voltage measurement and control component based on fluxgate technology. It can accurately measure DC, AC, pulse and various irregular voltages under the condition of complete isolation of the primary and secondary sides, which is a voltage sensor with extremely high measurement accuracy in the industrial field. It is mainly used in the fields of metrological verification and calibration, as well as rail transportation, power quality analysis, power analyzers, medical equipment, aerospace, naval vessels and other fields that require high sensitivity, high stability and high reliability.
Hoge nauwkeurigheid
Measuring Accuracy: 0.1%; Linearity: 0.05% Customized products up to 0.02%;
High Reliability
The primary and secondary insulation withstand voltage reaches 10KV; Low temperature drift, zero drift; High and low temperature resistance, can operate between -40℃ and 85℃;
Low Power Consumption
The primary current is less than 1mA; Can be customized less than 0.1mA;
Various Model
with various measurement range: 50V/100V/200V/500V/1000V/1500V/2000V/3000V
Customizable
Power supply voltage, output voltage, primary and secondary insulation, primary current limit and other parameters can be customized as per customer's requirements.
Typical Applications of Hangzhi HCV High Accuracy Voltage Sensor
Methoden voor openbaar vervoer, zoals hogesnelheidstreinen, stadsvervoersystemen en goederentreinen, bieden ideale en handige oplossingen om aan de groeiende vraag naar reizen te voldoen en tegelijkertijd milieuvervuiling en verkeersopstoppingen het hoofd te bieden. Om het probleem van het aandrijven en regelen van deze energiesystemen op te lossen, is technologie voor vermogenselektronica essentieel. De opkomende spoorwegindustrie blijft nieuwe technologische eisen stellen, zoals de behoefte aan energiemeting, de bewaking van spoorvoertuigen en de voortdurende verbetering van het onderhoud van de infrastructuur.
Hangzhi HCV AC & dC Voltage Transducers 0-10V output Catalog
Product Model | Primary rated DC voltage | Primary rated AC RMS voltage | Voedingsspanning | Verhouding (primair: secundair) | Rated secondary output | Secondary output load | Nauwkeurigheid | Lineariteit | Bandbreedte | Data papier |
---|---|---|---|---|---|---|---|---|---|---|
HCV50 | ±50V | 35V | 15V | 50:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV200 | ±200V | 140V | 15V | 200:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV500 | ±500V | 350V | 15V | 500:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV1000 | ±1000V | 707V | 15V | 1000:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV1500 | ±1500V | 1050V | 15V | 1500:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV2000 | ±2000V | 1400V | 15V | 2000:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV3000 | ±3000V | 2100V | 15V | 3000:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV4000 | ±4000V | 2800V | 15V | 4000:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV5000 | ±4000V | 3500V | 15V | 5000:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV6000 | ±4000V | 4200V | 15V | 6000:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
HCV10000 | ±4000V | 7000V | 15V | 10000:10 | ±10V | >2kΩ | 0.20% | 0.05% | 300kHz | HCV Voltage Transducers Catalog |
Note: Hangzhi is also able to customize the voltage transducers measurement range according to the customer’s requirement. Please feel free to contact us to request if the your requirements are not listed in the table above.