Hangzhi 0.01% Grade high precision DC Tester
The PIU high precision DC tester is developed on Hangzhi multi-point fluxgate current measurement technology. There are few models in the PIU family, and the maximum current can be measured by PIU testers can be up to DC10,000A. The measurement accuracy can reach 0.01%, even 0.005%. The testers are widely used for calibration of battery charging and discharging testing system.
- Voltage measurement range: ± (0.1V -1000V),maximum allowable error: ± 0.005%;
- Current measurement range: 10mA~10,000A, maximum allowable error: ± 0.005%
Application Overview
The battery charging and discharging testing system mainly consists of a microcomputer control unit, a charging unit (DC stable power supply), a discharging unit (DC electronic load), a charging/discharging switching unit, a measuring unit, etc.
The battery charging and discharging testing system is a device that regulates and protects battery charging and discharging by establishing charging and discharging parameters. The typical voltage range can be regulated throughout the
battery charging and discharging operation to prevent overcharging or discharging of the battery. The typical current range can be set. When the test reaches the specified value, it will immediately terminate. The battery charging and discharging testing system is primarily used to detect the battery’s current, voltage, capacity, internal resistance, charging and discharging temperature, battery cycle life, etc. There are many channels to choose from and different battery models and types can be tested at the same time.
The parameters of the battery charging and discharging testing system that must be measured
- Voltage range: 100mV~1000V, maximum allowable error: ± (0.02% -5%);
- Voltage measurement range: 100mV~1000V, maximum allowable error: ± (0.02% -5%);
- Setting range of charging and discharging current: 10mA~1500A, maximum allowable error: ± (0.05% -5%);
- The charging and discharging current measurement range is 10mA~1500A, with maximum allowable error: ±(0.05% -5%).
Product Catalog
Product model | Current Measurement Range | Voltage Measurement Range | Supply voltage | Accuracy | Catalog |
---|---|---|---|---|---|
PIU600 | DC±600A | DC1000V | AC85V~265V,50/60Hz | 0.01% | PIU DC Testers Catalog |
PIU1000 | DC±1000A | DC1000V | AC85V~265V,50/60Hz | 0.01% | PIU DC Testers Catalog |
PIU1500 | DC±1500A | DC1000V | AC85V~265V,50/60Hz | 0.01% | PIU DC Testers Catalog |
PIU2000 | DC±2000A | DC1000V | AC85V~265V,50/60Hz | 0.01% | PIU DC Testers Catalog |
PIU5000 | DC±5000A | DC1000V | AC85V~265V,50/60Hz | 0.01% | PIU DC Testers Catalog |
PIU10000 | DC±10000A | DC1000V | AC85V~265V,50/60Hz | 0.01% | PIU DC Testers Catalog |
Get In Touch with our Experts
Contact us directly via email info@hangzhiprecision.com or fill out the form below. We will respond as soon as possible.