Customise Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.

No cookies to display.

Hangzhi Precision

What is fluxgate current sensor? How does it work?

What is fluxgate Current Sensor? Working principle of fluxgate sensor

Under the action of positive and negative excitation current, the easy-to-saturation magnetic core is used to make the inductance of the magnetic core change with the magnitude of the excitation current, so that the magnetic flux of the magnetic core changes continuously.

The fluxgate current sensor uses the non-linear relationship between the magnetic induction intensity and the magnetic field intensity of the high magnetic permeability core in the measured magnetic field under the saturation excitation of the alternating magnetic field to measure the weak magnetic field. This physical phenomenon seems to be a “gate” to the measured ambient magnetic field. Through this “gate”, the corresponding magnetic flux is modulated and an induced electromotive force is generated. This phenomenon is used to measure the magnetic field generated by the current, so as to indirectly achieve the purpose of measuring the current.

working principle of fluxgate current sensor-hangzhi

Basic Principles of Fluxgate Sensor Operation

 

In the magnetic circuit, in order to detect a magnetic field equal to zero magnetic flux, the secondary coil must be excited by the necessary current. In the environment of zero magnetic flux, the current of the sensor is strengthened through the secondary coil, which is confirmed to be proportional to the measured primary current. . Ip=Ns. The Is ferromagnetic core and the auxiliary coil form a saturated inductor. In the case of zero magnetic flux, the detection of the sensor’s magnetic circuit is based on the change in the inductance of the inductor.

working principle of fluxgate current sensor-hangzhi 2

How does flux gate transducer technology evolves?

From the late 1960s to the early 1970s, fluxgate technology achieved a major breakthrough in accuracy for DC current measurement. The basic principle is to balance the magnetomotive force generated by the known current through the balance winding in the iron core and the magnetomotive force generated by the measured current to determine the magnitude of the measured current.

The principle structure of the fluxgate current sensor

The principle structure of the fluxgate current sensor is shown in Figure in the right.

A is a high-permeability material core; W1 and W2 are proportional windings; I1 and I2 are supplied by two independent power sources with DC currents of W1 and W2 respectively; Φ1 and Φ1 are generated by proportional windings W1 and W2, respectively The magnetic flux; Rm is the magnetic resistance.

According to the law of electromagnetic induction, for fluxgate current sensors, as long as there is a current passing through the sensor, there must be an induced magnetic field, and the induced magnetic field is approximately linear with the current passing through the sensor, as long as the induced magnetic field can be accurately measured. The magnitude and direction of the external current can be measured indirectly. In addition, through in-depth research, it is found that after the fluxgate current sensor modulates the ambient magnetic field generated by the external DC current into an even harmonic induced electromotive force, not only the even harmonic content has an approximately linear relationship with the external DC current within a certain range, but also The average value of the even harmonic content has an approximately linear relationship with the external DC current within a certain range.

Hangzhi's Innovation based on traditional flux gate Transducer technology

Existing fluxgate current sensors have the problems of complex structure, high cost, and inability to realize wideband current detection, which limits their popularization to a certain extent. After years of painstaking research, Shenzhen Hangzhi Precision company invented the multi-point zero magnetic flux technolog, published on IEEE website: https://ieeexplore.ieee.org/document/8601521 .Through the zero magnetic flux closed-loop control of excitation magnetic flux, DC magnetic flux, AC magnetic flux and high-frequency magnetic flux, it realized the control of DC current and high-frequency current. As well as the precise detection of alternating current, the current detection accuracy of the sensor is improved, and the production cost of the sensor is reduced.

Multi-point zero magnetic flux technology control system, including excitation module, excitation magnetic flux closed-loop control module and multi-flux closed-loop control module.

Multi-point fluxgate measurement system

The current Id in the circuit to be tested generates DC magnetic flux, AC magnetic flux, and high-frequency magnetic flux. The excitation oscillator outputs an alternating voltage signal of a preset frequency to the excitation unit to excite the excitation unit to generate excitation magnetic flux. The excitation magnetic flux detects the DC magnetic flux generated by the current Id to be measured, and outputs a DC magnetic flux signal corresponding to the DC magnetic flux.

The current Id in the circuit to be tested generates DC magnetic flux, AC magnetic flux, and high-frequency magnetic flux. The excitation oscillator outputs an alternating voltage signal of a preset frequency to the excitation unit to excite the excitation unit to generate excitation magnetic flux. The excitation magnetic flux detects the DC magnetic flux generated by the current Id to be measured, and outputs a DC magnetic flux signal corresponding to the DC magnetic flux.

Top Accuracy & Cost Effective

Fluxgate Precision Current Transducer Products

AIT600-SG HIGH PRECISION CURRENT TRANSDUCER

AIT High Precision Current Transducer

Range of Current Measurement: 1-10000A. Accuracy: 10ppm. Bandwidth: 800kHz/500kHz.

IIT700 industrial grade current transducer

IIT Industrial Current Transducer

Range of Current Measurement: 1-10000A. Accuracy: 0.02%. Bandwidth: 100kHz.

HIT 500-600 hall effect current sensor replacement

HIT Hall Effect Substituting Current Transducer

Range of Current Measurement: 1-3000A. Accuracy: 0.05%. Bandwidth: 100kHz.

HIT 500-600 hall effect current sensor replacement

RIT Leakage Current Transducer

Range of Current Measurement: 10mA-10A. Accuracy: 0.2%. Bandwidth: 100kHz.

DIT High Precision Digital Current Transdcuer

DIT High Precision Digital Current Transducer

Range of Current Measurement: 60A-2000A. Accuracy: 0.02%. Digital Signal Output: RS232/RS485.

high current transducer AIT

High Current Transducer

Range of Current Measurement: 2000-10000A. Accuracy: 50ppm. Bandwidth: 300kHz/50kHz.

BMS Automotive Current Transdcuer

BMS Automotive Current Transducer

Range of Current Measurement: 300-1500A. Accuracy: 0.5%. Output: CAN digital signal.

CAFR-A-NP PCB current sensor

CAFR PCB Current Sensors

Range of Current Measurement: 6-50A. Accuracy: 0.8%.

CIT High Precision Split Core Current Transdcuer

CIT High Precision Split Core Current Transducer

Range of Current Measurement: 100A-1500A. Accuracy: 0.05%. Bandwidth: 350kHz.

Get in touch with our experts

Contact us directly via email info@hangzhiprecision.com or fill out the form below. We will respond as soon as possible.

1 thought on “What is fluxgate current sensor? How does it work?”

  1. Pingback: what are the differences between fluxgate and hall effect current transducers? - Hangzhi Precision

Comments are closed.

en_GBEnglish (UK)
We've detected you might be speaking a different language. Do you want to change to:
en_US English
en_US English
es_ES Español
pt_PT Português
fr_FR Français
de_DE Deutsch
ru_RU Русский
ar العربية
nl_NL Nederlands
tr_TR Türkçe
pt_BR Português do Brasil
en_CA English (Canada)
en_GB English (UK)
ko_KR 한국어
ja 日本語
en_AU English (Australia)
de_AT Deutsch (Österreich)
pl_PL Polski
nl_BE Nederlands (België)
fr_BE Français de Belgique
da_DK Dansk
sv_SE Svenska
de_CH Deutsch (Schweiz)
it_IT Italiano
en_ZA English (South Africa)
ro_RO Română
hu_HU Magyar
cs_CZ Čeština
fi Suomi
id_ID Bahasa Indonesia
es_AR Español de Argentina
es_CL Español de Chile
es_PE Español de Perú
es_MX Español de México
el Ελληνικά
Close and do not switch language
Let's chat on WhatsApp

How can I help you? :)

17:59